Honda Civic/Acura Integra

from 1994 launch

Repair and operation of the car



Honda Tsivik
+ Cars of the mark of It Treats Full text and Honda Civic With care
+ Maintenance education
+ Regular maintenance
+ Motor
- To cool system and heating
   Specifications
   Antifreeze - general information
   Check of usefulness of functioning and substitution of the thermostat
   Check of a condition of the supporter (supporters) of the system of cooling and chain of his inclusion, substitution of the supporter (supporters)
   Removal and installation of an electric heater and wide tank of the system of cooling
   Removal and installation of the fridge of oil
   Check of a condition of the water bomb
   Substitution of the water bomb
   The check of usefulness of the functioning and substitution of the block of the sensor of the instrument of measuring of the temperature of cooling the liquid
   Check of usefulness of functioning of an electric motor of driving of the supporter of a heater and condition of component ones of his electric chain, substitution of component ones
   Removal and installation of an electric motor of the walk of the supporter of a heater
   Removal and installation of meeting of the panel of control of functioning of a heater and condicionador of air, agreement of a thread of driving
   Substitution of the conductor of heat of a heater
   Check of usefulness of functioning and service of systems of heating and air conditioning
   Check of an electric chain of an union of pressure of the compressor K/V
   Removal and installation of a desumidificador of receiver to / in
   Removal and installation of the compressor K/V
   Removal and installation of the condenser K/V
   Removal and installation of evaporador K/V with the wide valve
+ System of provision of power and launch
+ Electric motor equipment
+ Systems of control of the motor
+ Box of dislocation of gear
+ Union and ends of power
+ Brakes system
+ Support of the triangular form of interruption and direction
+ Body
+ Electric side equipment


5dfc58ab

Specifications

General parameters

Characteristic

Value

Expand of cooling the liquid

To see the Front Regular maintenance

Effort of a tension of a belt of driving

To see the Front Regular maintenance

Pressure of agreement of a covering of an electric heater, kgf/cm 2

0.1÷1.3

Temperature of opening of the thermostat, °C

91

Type of refrigerant liquid of the system of air conditioning

R-134a

The volume of refrigerant liquid that is subject to the petrol station in the system during the substitution of his component many people, ml

   Compressor

120÷140

   Condenser

120

   Evaporador

130

   Receiver Desumidificador

10

   Lines of refrigerator or hoses

10

Efforts of corseting itself of screwed connections, Nanômetro

Type of connection

Value

Pin of fixation of an arm of the creator to the water bomb

45

Thermostat that fits in pins of covering

12.2

The pins of the fixation of the union of the superior electric heater water with hose to the block

10.8

Pins of fixation of the water bomb to the block

12.2